General characteristics
Inner Conductor: |
Copper - clad Aluminium Diameter: |
1.9 mm |
Dielectric: |
Foam Polyethylene Diameter: |
4.5 mm |
Outer Conductor: |
Corrugated copper Outer Diameter: |
6.4 mm |
Jacket: |
Black High Fire resistant Low smoke Zero Halogen Compound Diameter: |
7.95 mm |
Ink marking: ACOME HPL 50-1/4SF LSOH HFR M5302 (UL) E352156 CATVR 13AWG 75 ℃ LOT X lot N° (+ Metric length)
Bending radius: | Operating | 45 mm – Min |
Installation | 25 mm – Min | |
Tensile Strength: | 500 N – Max | |
Weight: | 85 kg/km | |
Packaging: | 500 m |
Temperature range: | Operating | -40°C / +85°C |
Installation | -20°C / +60°C | |
Storage | -70°C / +85°C | |
Fire resistance: | UL 1666 | |
Smoke toxicity: | IEC 60754-2 | |
Smoke density: | IEC 61034 | |
Test methods: | IEC 60096-0-1, 61196-1, 60966-1 |
Impedance : 50 ± 1 Ω
Return loss :
- 400 ~ 500 MHz ≤ -26.5 dB
- 800 ~ 1000 MHz ≤ -26.5 dB
- 1700 ~ 2200 MHz ≤ -24 dB
- 2500 ~ 2700 MHz ≤ -23.5 dB
Capacitance: 80 pF/m
Passive Intermodulation : ≤-158 dBc
Velocity: 83%
Dielectric constant: 1.48
Screening effectiveness: > 120 dB
Operating frequency: ≤ 18 GHz
Peak power rating: 3.94 kW
Operating voltage: 0.6 kV RMS
Insulation Resistance: > 10000 MΩ.km
DC resistance:
- Inner conductor: ≤ 9.78 Ω/km
- Outer conductor: ≤ 6.90 Ω/km
Frequency (MHz) |
Attenuation (dB/100m) @ 20°C Typical |
Power kW @ 40°C-Ambient Temperature Inner conductor: 100°C |
30 |
3.16 |
3.13 |
80 |
5.21 |
1.89 |
150 |
7.19 |
1.37 |
450 |
12.75 |
0.77 |
824 |
17.58 |
0.56 |
900 |
18.44 |
0.54 |
960 |
19.09 |
0.52 |
1000 |
19.53 |
0.50 |
1500 |
24.34 |
0.40 |
1700 |
26.05 |
0.38 |
1800 |
26.93 |
0.37 |
1900 |
27.70 |
0.36 |
2000 |
28.52 |
0.35 |
2200 |
30.05 |
0.33 |
2300 |
30.79 |
0.32 |
2400 |
31.50 |
0.31 |
2500 |
32.27 |
0.30 |
3000 |
35.69 |
0.277 |
3300 |
37.73 |
0.262 |
3400 |
38.36 |
0.258 |
3500 |
39.02 |
0.25 |
3600 |
39.63 |
0.24 |
3800 |
40.86 |
0.23 |