M5306Z
HYPERCELL
General characteristics
|
Inner Conductor: |
Copper - clad Aluminium Diameter: |
2.8 mm |
|
Dielectric: |
Foam Polyethylene Diameter: |
6.9 mm |
|
Outer Conductor: |
Corrugated copper Outer Diameter: |
9.6 mm |
|
Jacket: |
Black High Fire resistant Low smoke Zero Halogen Compound Diameter: |
11.15 mm |
Ink marking: ACOME HPL 50-3/8SF LSOH HFR M5306 (UL) E352156 CATVR 10AWG 75℃ LOT X lot N° (+ Metric length)
| Bending radius: | Operating | 45 mm – Min |
| Installation | 25 mm – Min | |
| Tensile Strength: | 500 N – Max | |
| Weight: | 147 kg/km | |
| Packaging: | 500 m | |
| Temperature range: | Operating | -40°C / +85°C |
| Installation | -20°C / +60°C | |
| Storage | -70°C / +85°C | |
| Fire resistance: | UL 1666 | |
| Smoke toxicity: | IEC 60754-2 | |
| Smoke density: | IEC 61034 | |
| Test methods: | IEC 60096-0-1, 61196-1, 60966-1 | |
Impedance : 50 ± 1 Ω
Return loss :
- 400 ~ 500 MHz ≤ -26.5 dB
- 800 ~ 1000 MHz ≤ -26.5 dB
- 1700 ~ 2200 MHz ≤ -24 dB
- 2500 ~ 2700 MHz ≤ -23.5 dB
Capacitance: 80 pF/m
Passive Intermodulation : ≤-158 dBc
Velocity: 83%
Dielectric constant: 1.45
Screening effectiveness: > 120 dB
Operating frequency: ≤ 12 GHz
Peak power rating: 8.6 kW
Operating voltage: 0.9 kV RMS
Insulation Resistance: > 10000 MΩ.km
DC resistance:
- Inner conductor: ≤ 4.76 Ω/km
- Outer conductor: ≤ 4.95 Ω/km
|
Frequency (MHz) |
Attenuation (dB/100m) @ 20°C Typical |
Power kW @ 40°C-Ambient Temperature Inner conductor: 100°C |
|
30 |
2.27 |
3.06 |
|
80 |
3.75 |
1.88 |
|
150 |
5.16 |
1.36 |
|
450 |
9.14 |
0.78 |
|
824 |
12.60 |
0.56 |
|
900 |
13.20 |
0.54 |
|
960 |
13.62 |
0.53 |
|
1000 |
13.90 |
0.52 |
|
1500 |
17.35 |
0.42 |
|
1700 |
18.60 |
0.39 |
|
1800 |
19.20 |
0.37 |
|
1900 |
19.76 |
0.36 |
|
2000 |
20.30 |
0.35 |
|
2200 |
21.40 |
0.33 |
|
2300 |
21.95 |
0.32 |
|
2400 |
22.48 |
0.316 |
|
2500 |
23.0 |
0.31 |
|
3000 |
25.47 |
0.28 |
|
3300 |
26.90 |
0.26 |
|
3400 |
27.34 |
0.25 |
|
3500 |
27.79 |
0.24 |
|
3600 |
28.24 |
0.23 |
|
3800 |
29.18 |
0.21 |