General characteristics
Inner Conductor: | Copper – clad Aluminium | 4.8 mm |
Dielectric: | Foam Polyethylene | 11.9 mm |
Outer Conductor: | Corrugated copper | 13.7 mm |
Jacket: | Black High Fire resistant Low smoke Zero Halogen Compound | 16.0 mm |
Ink Marking: |
ACOME HYPERCELL COAX LSOH HFR HPL 50-1/2F FLEXIBLE M5322 LOT X lot N°(+Metric length) |
|
Bending radius: | Operating | 125 mm – Min |
Installation | 70 mm – Min | |
Tensile Strength: | 1100 N – Max | |
Weight: | 264 kg/km | |
Packaging: | 500 m |
Temperature range: | Operating | -40°C / +85°C |
Installation | -20°C / +60°C | |
Storage | -70°C / +85°C | |
Fire resistance: | NFC32070 2.2/RATP K26 | |
CPR: | B2ca-s1a,d1,a1 , EN50575 | |
Smoke toxicity: | IEC 60754-2 / NFC20-454 | |
Smoke density: | IEC 61034 | |
Test methods: | IEC 60096-0-1, 61196-1, 60966-1 |
Impedance : 50 ± 1 Ω
Return loss :
- 380 ~ 500 MHz ≤ -26.5 dB
- 694 ~ 960 MHz ≤ -26.5 dB
- 1700 ~ 2200 MHz ≤ -24 dB
- 2500 ~ 2700 MHz ≤ -23.5 dB
- 3400 ~ 3800 MHz ≤ -22 dB
Capacitance: 76 pF/m
Passive Intermodulation : ≤-160 dBc
Velocity: 88%
Dielectric constant: 1.32
Screening effectiveness: > 120 dB
Operating frequency: ≤ 8 GHz
Peak power rating: 40 kW
Operating voltage: 1.6 kV RMS
Insulation Resistance: > 10000 MΩ.km
DC resistance:
- Inner conductor: ≤ 1.60 Ω/km
- Outer conductor: ≤ 2.08 Ω/km
Frequency (MHz) |
Attenuation (dB/100m) @ 20°C Typical |
Power kW @ 40°C- Ambient Temperature Inner conductor: 100°C |
30 |
1.18 |
8.35 |
80 |
1.95 |
5.06 |
150 |
2.69 |
3.67 |
450 |
4.76 |
2.07 |
824 |
6.56 |
1.50 |
900 |
6.88 |
1.43 |
960 |
7.12 |
1.39 |
1000 |
7.28 |
1.35 |
1500 |
9.07 |
1.09 |
1700 |
9.71 |
1.02 |
1800 |
10.02 |
0.98 |
1900 |
10.32 |
0.95 |
2000 |
10.62 |
0.93 |
2200 |
11.19 |
0.88 |
2300 |
11.47 |
0.85 |
2400 |
11.75 |
0.84 |
2500 |
12.02 |
0.82 |
3000 |
13.34 |
0.74 |
3300 |
14.06 |
0.70 |
3400 |
14.28 |
0.69 |
3500 |
14.52 |
0.68 |
3600 |
14.75 |
0.64 |
3800 |
15.21 |
0.62 |
4500 |
16.80 |
0.55 |
5800 |
20.15 |
0.40 |
6000 |
20.25 |
0.36 |
8000 |
23.90 |
0.28 |