ACOLAN® COPPER FIREPROTECT
Applications
- 10 Gigabit high speed data transmission cables are designed for horizontal cable distribution local computer networks.
- These cables allow the use of the protocol supported by the class FA for the 10 GBASE-T applications.
- They are characterized of up to 1200 MHz.
- They are compatibles with PoE & PoE+, UPoE & 4PPoE (PoE++) applications.
See our White Paper on installation conditions on www.acome.com also available on demand.
General characteristics
|
Solid annealed red copper wire, AWG 23 Foam skin Pe insulation Æ ≤ 1.47 mm
|
|
Cable assembly in Twisted Pairs |
|
Pet/Alu foil around each pair |
|
4 pairs screening assembly |
|
Tinned copper braid |
|
LSOH-FR : Low Smoke « Zero » Halogen – Flame Retardant |
Designation ACOLAN FIREPROTECT |
Ref. |
Colour |
Diameter |
Weight |
Superior calorificcapacity (PCS) |
Max pulling tension |
|
mm |
Kg/km |
MJ/km |
KWh/m |
N |
|||
1200 SF-P 4P LSOH-FR * |
R7483A |
Ivory |
7.50 |
55 |
525 |
0,146 |
95 |
1200 SFD-P 2x4P LSOH-FR * |
R7484A |
Ivory |
7.50 x 15.50 |
115 |
1095 |
0,304 |
190 |
*EC verified : structure 4P & 2x4P
Characteristics |
Values |
|
Bending radius |
Dynamic (installation) |
≥ 60 mm |
Static (installed) |
≥ 30 mm |
|
Temperature range |
In service |
- 20°C at + 60°C |
At the installation |
0°C at + 50°C |
|
Transport and storage |
0°C at + 50°C |
Characteristics |
Values |
||
Complete conductor resistance |
|
≤ 140 Ω / km |
|
Resistance unbalance |
|
≤ 2 % |
|
Dielectric strength |
Continuous current |
1kV during1 minute = No breakdown |
|
Insulation resistance |
(500 V) |
≥ 5000 MΩ . km |
|
Capacitance unbalance |
Real-ground |
≤ 1600 pF / km |
|
Characteristic impedance |
at 100 MHz |
100 ± 5 Ω |
|
Velocity |
nominal |
78 % |
|
Coupling attenuation |
|
≥ 85 dB |
TYPE 1 |
Transfer impedance |
At 1 MHz |
≤ 8 mΩ / m |
GRADE 1 |
At 10 MHz |
≤ 8 mΩ / m |
||
At 30 MHz |
≤ 10 mΩ / m |
||
At 100 MHz |
≤ 20 mΩ / m |
||
Segregation classification acc. to EN 50174.2 |
|
“d” |
Norms and standards
EC
Applications
IEEE 802.3 :10Base-T; 100Base-TX;1000Base-T; 2,5GBase-T ; 5GBase-T ; 10GBase –T
IEEE 802.3 af (PoE) / 802.3 at (PoE+) / 802.3 bt (4PPoE 90W)
IEEE 802.5 / FDDI / ATM / RNIS
Cables
IEC 61156-5 ed.2 / EN 50288-9-1
Cabling system standard
ISO/IEC 11801 2nd ed. / EN 50173-1
Cabling system installation standard
EN 50174
Directive / Regulation
RoHS 2011/65/UE
REACH 1907/2006/EC
Europe
Type |
Euroclass |
Standards |
Declaration of performance |
|
4P |
Cca-s1,d2,a1 |
IEC 60332-1, EN 50399, IEC 60754-2 |
17SFTP008 |
|
2x4P |
17SFTP009 |
Outside Europe
No flame propagation |
IEC 60332-1 / EN 60332-1 |
No fire propagation |
IEC -60332-3-24 / EN 60332-3-24 |
Low smoke opacity |
IEC 61034-2 / EN 61034-2 |
Low gas corrosivity |
IEC 60754-2 / EN 60754-2 |
Low toxicity |
IEC 60754-1 / EN 60754-1 |
Recommendations
Type |
References |
Individual |
Expedition |
||||
Type |
Weight |
EAN code |
Type |
Weight |
EAN code |
||
4P LSOH-FR |
R7483A-T500 |
Drum KT of 500 m |
30 kg |
3700223666959 |
18 drums |
550 kg |
3700223679423 |
R7483A-T1000 |
Drum XL of 1000 m |
60 kg |
3700223666966 |
4 drums |
255 kg |
3700223679416 |
|
2 x 4P LSOH-FR |
R7484A-T500 |
Drum XL of 500 m |
62 kg |
3700223666973 |
4 drums |
260 kg |
3700223679638 |
R7484A-T1000 |
Drum AC of 1000 m |
125 kg |
3700223666980 |
4 drums |
510 kg |
3700223679409 |