Product

R7435B-T500
ACOLAN COPPER

SF/UTP Cat.5e 200 MHz 4P LSOH-FR DRUM 500m - BLACK

Applications

  • High speed data transmission cables are designed for horizontal cable distribution local computer networks.
  • Protected by a black UV resistant LSOH-FR sheath for outdoor use.
  • These cables are permitted the protocol supported by the class D.
  • They are characterized of up to 200 MHz.
  • They are compatibles with PoE & PoE+, UPoE applications.

General characteristics

Characteristics_acome_acolan_copper

  1. Conductor

Solid annealed red copper wire, AWG 24
Colored polyethylene insulation  ≤ 1.00 mm

 

  1. Cable element

Cable assembly in Twisted Pairs

      3. Cable assembly

4 pairs assembly

      4. Screen

Pet/Alu foil and tinned copper braid (80%)

      5. External sheath

LSOH-FR UV stabilize
Low Smoke « Zero » Halogen - Flame Retardant

GENERAL

Designation

ACOLANâ

Ref.

Colour

Diameter

Weight

Superior calorificcapacity

(PCS)

Max pulling tension

mm

Kg/km

MJ/km

KWh/m

N

200 SFU-S 4P LSOH-FR IN/OUT

R7435B

Black

6.80 to 7.10

69

665

0,185

500

MECHANICAL

            Characteristics

Values

Bending radius

Dynamic (installation)

≥ 60 mm

Static (installed)

≥ 30 mm

Temperature range

In service

- 40°C at + 75°C

At the installation

- 20°C at + 60°C

Transport and storage

- 40°C at + 75°C

Waterproofness Minimum IP67

 

ELECTRICAL

            Characteristics

Values

Complete conductor resistance

Any conductor Shield

≤ 95 Ω / km

≤ 10.50 Ω / km

Resistance unbalance

 

≤ 2 %

Dielectric strength

Continuous current

1.5 kV during 1 minute = no breakdown

5 kV DC during 3 seconds = no breakdown

Insulation resistance

(500 V)

≥ 5000 MΩ  . km

Capacitance unbalance

Real-ground

≤ 1600 pF / km

Characteristic impedance

at 100 MHz

100 ±  5 Ω 

Velocity

nominal

66 %

Coupling attenuation

 

≥ 85 dB

TYPE 1

Transfert impedance

 

at 1 MHz ≤ 10 MΩ  / m GRADE 1
at 10 MHz ≤ 10 MΩ  / m

at 30 MHz

≤ 20 MΩ  / m
at 100 MHz ≤ 30 MΩ  / m
Segregation classification acc. EN 50174-2   "d"

 

Transmission characteristics at 20° C

Frequency
(MHz)
  4 10 20 62.5 100 155** 200**
Attenuation (dB/100m) Typical value 3.8 6 8.5 15.2 19.5 25 28
Imposition (max)* 4.1 6.5 9.3 17 22 - -
Next (dB)  Typical value 63 57 52 45 42 39 37
Imposition (min)* 56.3 50.3 45.8 38.4 35.3 - -
ACR (dB) Typical value 59.2 51 43.5 29.8 22.5 14 9
Imposition (min)* 52.2 43.8 36.5 21.4 13.3 - -
PS Next (dB) Typical value 60 54 49 42 39 36 34
Imposition (min)* 53.3 47.3 42.8 35.4 32.3 - -
ELFEXT (dB/100 m) Typical value 63 55 48 39 35 31 29
Imposition (min)* 52 44 38 28 24 - -
PS ELFEXT (dB/100 m) Typical value 60 52 45 36 32 28 26
Imposition (min)* 49 41 35 25 21 - -
Return Loss (dB) Typical value 25 25 25 23.8 23 22 21
Imposition (min)* 23 25 25 21.5 20.1 - -

 

 

 

 

 

Norms and standards

GENERAL

   logo poe    logo ce

Application
IEEE 802.3: 10Base-T, 100Base-T ;1000Base-T ;
IEEE 802.3 af (PoE) / 802.3 at (PoE+)
IEEE 802.5 /  FDDI / ATM / RNIS

Cables
IEC 61156-5  / EN 50288-2-1

Cabling system standard
ISO/IEC 11801 2nd ed. / EN 50173-1 / TIA-568.2-D

Cabling system installation standards 
EN 50174

Directive / Regulation
RoHS 2011/65/UE
REACH 1907/2006/EC

EUROCLASS

EUROCLASSE ECA

FIRE BEHAVIOUR

Europe 

Type

Euroclass

Standards

Declaration of performance

4P

Eca

IEC 60332-1

17SFUTP03

Zone de Texte: www.acome.fr

Outside Europe

No flame propagation

IEC 60332-1 / EN 60332-1

Low smoke opacity

IEC 61034-2 / EN 61034-2

Low gas corrosivity

IEC 60754-2 / EN 60754-2

Low toxicity

IEC 60754-1 / EN 60754-1

Recommendations

DELIVERY LENGTH
Type

References

Individual

Expedition

Type

Weight

EAN code

Quantity

Weight

EAN code

4P

R7435B-T500

Drum KT of 500 m

37 kg

3700223679553

18  drums

681 kg

3700223679546

R7435B-T1000 Drum XC of 1000 m 74 kg 3700223679539 6 drums 457 kg 3700223679522

You want more information ?