Product
Low voltage power cable_Aluminum conductor_T105 Aluminum Power PVC - 10 à 120 mm²

T105 Aluminum Power PVC - 10 à 120 mm²

Power cables with aluminium conductor insulated with PVC.
10 - 120 mm²

Benefits

  • High weight reduction
  • Loss effective conductor

General characteristics

Conductor

  •  Aluminum alloy 1370

Insulation

  • Lead-free PVC class T105
Conductor                                                                Cable
Cross section Number of strands Max. diameter of strands Max. diameter Max. conductor resistance Insulation wall thickness Min. external diameter Max. external diameter Standard delivery length
mm²   mm mm Ω/km@ 20°C mm mm mm m
Thin wall
10 50 0.52 4.50 3.03 0.48 5.40 5.80 1 300
12 60 0.52 5.40 2.53 0.48 5.80 6.50 1 000
16 78 0.52 5.80 1.93 0.52 6.50 7.00 1 000
20 96 0.52 6.90 1.59 0.52 7.00 1 000 750
25 120 0.52 7.20 1.24 0.52 7.30 7.80 700
30 144 0.52 8.30 1.08 0.52 8.20 8.70 550
35 168 0.52 8.50 0.878 0.64 9.00 9.60 550
40 192 0.52 9.60 0.788 0.64 9.80 10.40 450
50 240 0.52 10.50 0.610 0.71 10.40 11.10 350
60 288 0.52 11.60 0.525 0.72 11.50 12.20 750
Thick Wall
30 144 0.52 8.30 1.08 1.04 9.70 10.90 400
35 168 0.52 8.50 0.878 1.04 9.60 11.60 300
40 192 0.52 9.60 0.788 1.12 11.20 12.40 300
50 240 0.52 10.50 0.610 1.20 11.50 13.50 250
60 288 0.52 11.60 0.525 1.20 13.40 14.60 600
70 344 0.52 12,5 0.432 1.20 13.50 15.50 500
85 408 0.52 13.20 0.365 1.28 14.80 16.80 400
95 456 0.52 14.80 0.327 1.28 16 18 350
120 296 0.72 15.40 0.255 1.28 17.7 19.7 350

Norms and standards

General standards
  •  According to ISO 6722-2
  • Ford ES-BK2T-1A348-AA