Low voltage power cable_Aluminum conductor_Conducteur aluminium_T150 Aluminum Flex - 10 à 85 mm²

T150 Aluminum Flex - 10 à 85 mm²

Power cables with aluminum conductor insulated with flexible triple layer sheath.
10 - 85 mm²

Benefits

  • High weight reduction
  • Higher flexibility: innovative triple layer insulation
  • Safer: resistance short circuits (265°C during one hour)
 

General characteristics

Conductor

  • Aluminium alloy 1370

Insulation

  • Crosslinked PE/EBA/PE class T150
Conductor                                                                 Cable
Cross section Number of strands Max. diameter of strands Max. diameter Max. conductor resistance Insulation wall thickness Min. external diameter Max. external diameter Standard delivery length
mm²   mm mm Ω/km@ 20°C mm mm mm m
Thin Wall
10 50 0.52 4.50 3.03 0.48 5.40 5.80 1 300
16 78 0.52 5.50 1.93 0.52 6.50 7.00 1 000
20 96 0.52 6.10 1.59 0.52 7.30 7.80 750
25 120 0.52 7.00 1.24 0.52 8.20 8.70 350
30 144 0.52 7.40 1.08 0.64 9.00 9.60 450
35 168 0.52 8.30 0.878 0.64 9.80 10.40 350
40 192 0.52 8.90 0.788 0.72 10.40 11.10 300
50 240 0.52 9.80 0.613 0.72 11.50 12.20 250
60 288 0.52 10.50 0.525 0.80 12.50 13.30 200
70 344 0.52 11.60 0.432 0.80 13.50 14.40 180
85 420 0.52 13.20 0.365 0.90 14.40 15.30 500
 

Norms and standards

General standards
  • ISO 6722-2
  • Ford ES-BK2T-1A348-AA

You want more information ?

Related products