Conductor
Insulation
Conductor Cable | ||||||||
Cross section | Number of strands | Max. diameter of strands | Max. diameter | Max. conductor resistance | Insulation wall thickness | Min. external diameter | Max. external diameter | Standard delivery length |
mm² | mm | mm | Ω/km@ 20°C | mm | mm | mm | m | |
Thin wall | ||||||||
10 | 320 | 0.20 | 4 | 1.82 | 0.48 | 5.30 | 6 | 1 300 |
12 | 384 | 0.20 | 4.50 | 1.52 | 0.48 | 5.80 | 6.50 | 1 100 |
16 | 504 | 0.20 | 5 | 1.16 | 0.52 | 6.40 | 7 | 1 000 |
20 | 600 | 0.20 | 5.45 | 0.955 | 0.52 | 7 | 7.80 | 750 |
25 | 784 | 0.20 | 6.40 | 0.743 | 0.52 | 7.90 | 8.70 | 550 |
30 | 896 | 0.20 | 7 | 0.647 | 0.64 | 8.70 | 9.60 | 450 |
35 | 1 120 | 0.20 | 7.50 | 0.527 | 0.64 | 9.40 | 10.40 | 400 |
40 | 1 216 | 0.20 | 8.20 | 0.473 | 0.71 | 10 | 11.10 | 300 |
50 | 1 600 | 0.20 | 9 | 0.368 | 0.71 | 11 | 12.60 | 250 |
60 | 1 840 | 0.20 | 10 | 0.315 | 0.80 | 12 | 13.30 | 200 |
70 | 2 272 | 0.20 | 11.30 | 0.259 | 0.80 | 13 | 14.40 | 150 |
95 | 2 960 | 0.20 | 12.6 | 0.80 | 16.00 | 18.00 | 100 | |
Thick wall | ||||||||
10 | 320 | 0.20 | 4 | 1.82 | 0.80 | 5.90 | 6.50 | 1 100 |
16 | 504 | 0.20 | 5 | 1.16 | 0.80 | 7.70 | 8.30 | 650 |
25 | 784 | 0.20 | 6.4 | 0.743 | 1.04 | 9.40 | 10 | 380 |
35 | 1 120 | 0.20 | 7.5 | 0.527 | 1.04 | 10.30 | 11 | 300 |
50 | 1 600 | 0.20 | 9.5 | 0.368 | 1.20 | 12.4 | 13.2 | 200 |
70 | 2 272 | 0.20 | 11.30 | 0.259 | 1.20 | 13.4 | 15.1 | 150 |
95 | 1 930 | 0.20 | 12.60 | 0.196 | 1.28 | 16.4 | 17.4 | 100 |